| Rifatron 5brid DVR contains an unauthenticated vulnerability in the animate.cgi script that allows unauthorized access to live video streams. Attackers can exploit the Mobile Web Viewer module by specifying channel numbers to retrieve sequential video snapshots without authentication. |
| Beward N100 M2.1.6.04C014 contains an unauthenticated vulnerability that allows remote attackers to access live video streams without credentials. Attackers can directly retrieve the camera's RTSP stream by exploiting the lack of authentication in the video access mechanism. |
| A vulnerability in XAMPP, developed by Apache Friends, version 1.7.3's default WebDAV configuration allows remote authenticated attackers to upload and execute arbitrary PHP code. The WebDAV service, accessible via /webdav/, accepts HTTP PUT requests using default credentials. This permits attackers to upload a malicious PHP payload and trigger its execution via a subsequent GET request, resulting in remote code execution on the server. |
| A vulnerability has been discovered in AC Smart II where passwords can be changed without authorization. This page contains a hidden form for resetting the administrator password. The attacker can manipulate the page using developer tools to display and use the form. This form allows you to change the administrator password without verifying login status or user permissions. |
| In the moPS App through 1.8.618, all users can access administrative API endpoints without additional authentication, resulting in unrestricted read and write access, as demonstrated by /api/v1/users/resetpassword. |
| FLIR Thermal Camera F/FC/PT/D Stream firmware version 8.0.0.64 contains an unauthenticated vulnerability that allows remote attackers to access live camera streams without credentials. Attackers can exploit the vulnerability to view unauthorized thermal camera video feeds across multiple camera series without requiring any authentication. |
| WF2220 exposes endpoint /cgi-bin-igd/netcore_get.cgi that returns configuration of the device to unauthorized users. Returned configuration includes cleartext password.
The vendor was contacted early about this disclosure but did not respond in any way. |
| In version 0.4.1 of danswer-ai/danswer, a vulnerability exists where a basic user can create credentials and link them to an existing connector. This issue arises because the system allows an unauthenticated attacker to sign up with a basic account and perform actions that should be restricted to admin users. This can lead to excessive resource consumption, potentially resulting in a Denial of Service (DoS) and other significant issues, impacting the system's stability and security. |
| FLIR Brickstream 3D+ 2.1.742.1842 contains an unauthenticated vulnerability in the ExportConfig REST API that allows attackers to download sensitive configuration files. Attackers can exploit the getConfigExportFile.cgi endpoint to retrieve system configurations, potentially enabling authentication bypass and privilege escalation. |
| A vulnerability has been identified in which Rancher does not automatically clean up a user which has been deleted from the configured authentication provider (AP). This characteristic also applies to disabled or revoked users, Rancher will not reflect these modifications which may leave the user’s tokens still usable. |
| An unauthenticated remote attacker can cause a Denial of Service by turning off the output of the UPS via Modbus command. |
| Due to missing authentication, SAP HANA 2.0 (hdbrss) allows an unauthenticated attacker to call a remote-enabled function that will enable them to view information. As a result, it has a low impact on the confidentiality but no impact on the integrity and availability of the system. |
| In WODESYS WD-R608U router (also known as WDR122B V2.0 and WDR28) due to lack of authentication in the configuration change module in the adm.cgi endpoint, the unauthenticated attacker can execute commands including backup creation, device restart and resetting the device to factory settings.
The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version WDR28081123OV1.01 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable. |
| A web application for configuring the controller is accessible at a specific path. It contains an endpoint that allows a high privileged remote attacker to read files from the system’s file structure. |
| The privileged user could log in without sufficient credentials after enabling an application protocol. This security issue has been fixed in the latest script patch latest version of of Eaton BLSS (7.3.0.SCP004). |
| TEM Opera Plus FM Family Transmitter allows access to an unprotected endpoint that allows MPFS File System binary image upload without authentication. This file system serves as the basis for the HTTP2 web server module but is also used by the SNMP module and is available to other applications that require basic read-only storage capabilities. This can be exploited to overwrite the flash program memory that holds the web server's main interfaces and execute arbitrary code. |
| OPW Fuel Management Systems SiteSentinel
could allow an attacker to bypass authentication to the server and obtain full admin privileges. |
| TSA developed by Changing has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to read, modify, and delete database contents. |
| A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.40), SICORE Base system (All versions < V1.4.0). Affected devices allow a remote authenticated user or an unauthenticated user with physical access to downgrade the firmware of the device. This could allow an attacker to downgrade the device to older versions with known vulnerabilities. |
| The Control-M/Agent is vulnerable to unauthenticated remote code execution, arbitrary file read and write and similar unauthorized actions when mutual SSL/TLS authentication is not enabled (i.e. in the default configuration).