Search Results (1013 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-53756 2026-04-15 N/A
This vulnerability exists in Digisol DG-GR6821AC Router due to cleartext transmission of credentials in its web management interface. A remote attacker could exploit this vulnerability by intercepting the network traffic and capturing cleartext credentials. Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the targeted device.
CVE-2024-47789 1 D3dsecurity 1 D8801 2026-04-15 N/A
** UNSUPPORTED WHEN ASSIGNED ** This vulnerability exists in D3D Security IP Camera D8801 due to usage of weak authentication scheme of the HTTP header protocol where authorization tag contain a Base-64 encoded username and password. A remote attacker could exploit this vulnerability by crafting a HTTP packet leading to exposure of user credentials of the targeted device. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.
CVE-2025-27722 2026-04-15 5.9 Medium
Cleartext transmission of sensitive information issue exists in Wi-Fi AP UNIT 'AC-WPS-11ac series'. If exploited, a man-in-the-middle attack may allow a remote unauthenticated attacker to eavesdrop the communication and obtain the authentication information.
CVE-2024-50624 1 Kde 1 Kmail 2026-04-15 5.9 Medium
ispdbservice.cpp in KDE Kmail before 6.2.0 allows man-in-the-middle attackers to trigger use of an attacker-controlled mail server because cleartext HTTP is used for a URL such as http://autoconfig.example.com or http://example.com/.well-known/autoconfig for retrieving the configuration. This is related to kmail-account-wizard.
CVE-2025-52586 1 Eg4 Electronics 7 Eg4 12000xp, Eg4 12kpv, Eg4 18kpv and 4 more 2026-04-15 6.9 Medium
The MOD3 command traffic between the monitoring application and the inverter is transmitted in plaintext without encryption or obfuscation. This vulnerability may allow an attacker with access to a local network to intercept, manipulate, replay, or forge critical data, including read/write operations for voltage, current, and power configuration, operational status, alarms, telemetry, system reset, or inverter control commands, potentially disrupting power generation or reconfiguring inverter settings.
CVE-2025-52351 2026-04-15 8.8 High
Aikaan IoT management platform v3.25.0325-5-g2e9c59796 sends a newly generated password to users in plaintext via email and also includes the same password as a query parameter in the account activation URL (e.g., https://domain.com/activate=xyz). This practice can result in password exposure via browser history, proxy logs, referrer headers, and email caching. The vulnerability impacts user credential confidentiality during initial onboarding.
CVE-2025-43704 1 Veritas 1 Data Insight 2026-04-15 4.7 Medium
Arctera/Veritas Data Insight before 7.1.2 can send cleartext credentials when configured to use HTTP Basic Authentication to a Dell Isilon OneFS server.
CVE-2022-32510 1 Nuki 1 Bridge 2026-04-15 7.1 High
An issue was discovered on certain Nuki Home Solutions devices. The HTTP API exposed by a Bridge used an unencrypted channel to provide an administrative interface. A token can be easily eavesdropped by a malicious actor to impersonate a legitimate user and gain access to the full set of API endpoints. This affects Nuki Bridge v1 before 1.22.0 and v2 before 2.13.2.
CVE-2025-42603 2026-04-15 N/A
This vulnerability exists in the Meon KYC solutions due to transmission of sensitive data in plain text within the response payloads of certain API endpoints. An authenticated remote attacker could exploit this vulnerability by intercepting API response that contains unencrypted sensitive information belonging to other users. Successful exploitation of this vulnerability could allow remote attacker to impersonate the target user and gain unauthorized access to the user account.
CVE-2024-12378 2026-04-15 9.1 Critical
On affected platforms running Arista EOS with secure Vxlan configured, restarting the Tunnelsec agent will result in packets being sent over the secure Vxlan tunnels in the clear.
CVE-2025-12508 2 Bizerba, Microsoft 2 Brain2, Active Directory 2026-04-15 8.4 High
When using domain users as BRAIN2 users, communication with Active Directory services is unencrypted. This can lead to the interception of authentication data and compromise confidentiality.
CVE-2025-50110 2026-04-15 8.8 High
An issue was discovered in the method push.lite.avtech.com.AvtechLib.GetHttpsResponse in AVTECH EagleEyes Lite 2.0.0, the GetHttpsResponse method transmits sensitive information - including internal server URLs, account IDs, passwords, and device tokens - as plaintext query parameters over HTTPS
CVE-2024-10973 1 Redhat 3 Build Keycloak, Jboss Enterprise Application Platform, Jbosseapxp 2026-04-15 5.7 Medium
A vulnerability was found in Keycloak. The environment option `KC_CACHE_EMBEDDED_MTLS_ENABLED` does not work and the JGroups replication configuration is always used in plain text which can allow an attacker that has access to adjacent networks related to JGroups to read sensitive information.
CVE-2025-6180 1 Strongdm 1 Sdm-cli 2026-04-15 N/A
The StrongDM Client insufficiently protected a pre-authentication token. Attackers could exploit this to intercept and reuse the token, potentially redeeming valid authentication credentials through a race condition.
CVE-2025-0631 2026-04-15 N/A
A Credential Exposure Vulnerability exists in the above-mentioned product and version. The vulnerability is due to using HTTP resulting in credentials being sent in clear text.
CVE-2025-0432 2026-04-15 5.7 Medium
EWON Flexy 202 transmits user credentials in clear text with no encryption when a user is added, or user credentials are changed via its webpage.
CVE-2024-8059 2026-04-15 4.3 Medium
IPMI credentials may be captured in XCC audit log entries when the account username length is 16 characters.
CVE-2024-5631 2026-04-15 N/A
Longse NVR (Network Video Recorder) model NVR3608PGE2W, as well as products based on this device, are transmitting user's login and password to a remote control service without using any encryption. This enables an on-path attacker to eavesdrop the credentials and subsequently obtain access to the video stream.  The credentials are being sent when a user decides to change his password in router's portal.
CVE-2020-36917 2026-04-15 7.5 High
iDS6 DSSPro Digital Signage System 6.2 contains a sensitive information disclosure vulnerability that allows remote attackers to intercept authentication credentials through cleartext cookie transmission. Attackers can exploit the autoSave feature to capture user passwords during man-in-the-middle attacks on HTTP communications.
CVE-2024-46505 2026-04-15 9.1 Critical
Infoblox BloxOne v2.4 was discovered to contain a business logic flaw due to thick client vulnerabilities.