| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| PLANEX CS-QP50F-ING2 smart cameras expose a configuration backup interface over HTTP that does not require authentication. A remote, unauthenticated attacker can directly retrieve a compressed configuration backup file from the device. The backup contains sensitive configuration information, including credentials, allowing an attacker to obtain administrative access to the camera and compromise the confidentiality of the monitored environment. |
| Insufficient authentication in user account management in Yugabyte Platform allows local network attackers with a compromised user session to change critical security information without re-authentication. An attacker with user session and access to application can modify settings such as password and email without being prompted for the current password, enabling account takeover. |
| A Missing Authentication for Critical Function vulnerability in the GRUB configuration used B&R APROL <4.4-01 may allow an unauthenticated physical attacker to alter the boot configuration of the operating system. |
| An Incorrect Implementation of Authentication Algorithm and Exposure of Data Element to Wrong Ses-sion vulnerability in the session handling used in B&R APROL <4.4-00P5 may allow an authenticated network attacker to take over a currently active user session without login credentials. |
| On Mercku M6a devices through 2.1.0, session tokens remain valid for at least months in some cases. |
| Uniweb/SoliPACS WebServer developed by EBM Technologies has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to access a specific page to obtain user group names. |
| A low-privileged local attacker can exploit improper permissions on nssm.exe to escalate their privileges and gain administrative access. |
| A code execution security issue exists in the affected product. An attacker with physical access could abuse the maintenance menu of the controller with a crafted payload. The security issue can result in arbitrary code execution. |
| Improper resource management in firmware of some Solidigm DC Products may allow an attacker with local or physical access to gain un-authorized access to a locked storage device. |
| An unauthenticated remote attacker can gain access to the cloud API due to a lack of authentication for a critical function in the affected devices. Availability is not affected. |
| The Control-M/Agent is vulnerable to unauthenticated remote code execution, arbitrary file read and write and similar unauthorized actions when mutual SSL/TLS authentication is not enabled (i.e. in the default configuration).
NOTE:
* The vendor believes that this vulnerability only occurs when documented security best practices are not followed. BMC has always strongly recommended to use security best practices such as configuring SSL/TLS between Control-M Server and Agent.
* The vendor notifies that Control-M/Agent is not impacted in Control-M SaaS |
| The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps.
This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication:
- Re-configure Access Managers (e.g. remove alarming system requirements)
- Freely re-configure the inputs and outputs
- Open all connected doors permanently
- Open all doors for a defined time interval
- Change the admin password
- and many more
Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet. |
| Tellion HN-2204AP routers contain an unauthenticated configuration disclosure vulnerability in the /cgi-bin/system_config_file management endpoint. The endpoint allows remote retrieval of a compressed configuration archive without requiring authentication or authorization. The exposed configuration may include administrative credentials, wireless keys, and other sensitive settings, enabling an unauthenticated attacker to obtain information that can facilitate further compromise of the device or network. |
| An unrestricted file upload vulnerability exists in BuilderEngine 3.5.0 via the integration of the elFinder 2.0 file manager and its use of the jQuery File Upload plugin. The plugin fails to properly validate or restrict file types or locations during upload operations, allowing an attacker to upload a malicious .php file and subsequently execute arbitrary PHP code on the server under the context of the web server process. While the root vulnerability lies within the jQuery File Upload component, BuilderEngine’s improper integration and lack of access controls expose this functionality to unauthenticated users, resulting in full remote code execution. |
| A remote code execution vulnerability exists in multiple Netcore and Netis routers models with firmware released prior to August 2014 due to the presence of an undocumented backdoor listener on UDP port 53413. Exact version boundaries remain undocumented. An unauthenticated remote attacker can send specially crafted UDP packets to execute arbitrary commands on the affected device. This backdoor uses a hardcoded authentication mechanism and accepts shell commands post-authentication. Some device models include a non-standard implementation of the `echo` command, which may affect exploitability. |
| Dongyoung Media DM-AP240T/W wireless access points contain an unauthenticated configuration disclosure vulnerability in the /cgi-bin/sys_system_config management endpoint. The endpoint allows remote retrieval of a compressed configuration archive without requiring authentication or authorization. The exposed configuration may include administrative credentials and other sensitive settings, enabling an unauthenticated attacker to obtain information that can facilitate further compromise of the device or network. |
| The software tools used by service personnel to test & calibrate the ventilator do not support user authentication. An attacker with access to the Service PC where the tools are installed could obtain diagnostic information through the test tool or manipulate the ventilator's settings and embedded software via the calibration tool, without having to authenticate to either tool. This could result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance. |
| An issue in WoFit v.7.2.3 allows a remote attacker to obtain sensitive information via the firmware update process |
| On the exos 9300 server, a SOAP API is reachable on port 8002. This API does not require any authentication prior to sending requests. Therefore, network access to the exos server allows e.g. the creation of arbitrary access log events as well as querying the 2FA PINs associated with the enrolled chip cards. |
| The ISOinsight from Netvision has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to access certain system functions. These functions include viewing the administrator list, viewing and editing IP settings, and uploading files. |