Search Results (4730 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-8525 1 Automatedlogic 1 Webctrl 2026-04-15 N/A
An unrestricted upload of file with dangerous type in Automated Logic WebCTRL 7.0 could allow an unauthenticated user to perform remote command execution via a crafted HTTP POST request which could lead to uploading a malicious file.
CVE-2025-15579 1 Opentext 1 Directory Services 2026-04-15 N/A
Deserialization of Untrusted Data vulnerability in OpenText™ Directory Services allows Object Injection.  The vulnerability could lead to remote code execution, denial of service, or privilege escalation. This issue affects Directory Services: before 24.4.16, from 25.1 before 25.1.9, from 25.2 before 25.2.9, from 25.3 before 25.3.8, from 25.4 before 25.4.5, from 26.1 before 26.1.2.
CVE-2025-0129 2026-04-15 N/A
An improper exception check in Palo Alto Networks Prisma Access Browser allows a low privileged user to prevent Prisma Access Browser from applying it's Policy Rules. This enables the user to use Prisma Access Browser without any restrictions.
CVE-2020-37135 3 Amss++ Project, Amss\+\+ Project, Amssplus 3 Amss++, Amss\+\+, Amss Plus 2026-04-15 7.5 High
AMSS++ 4.7 contains an authentication bypass vulnerability that allows attackers to access administrative accounts using hardcoded credentials. Attackers can log in with the default admin username and password '1234' to gain unauthorized administrative access to the system.
CVE-2023-32188 1 Neuvector 1 Neuvector 2026-04-15 N/A
A user can reverse engineer the JWT token (JSON Web Token) used in authentication for Manager and API access, forging a valid NeuVector Token to perform malicious activity in NeuVector. This can lead to an RCE.
CVE-2025-29757 2026-04-15 N/A
An incorrect authorisation check in the the 'plant transfer' function of the Growatt cloud service allowed a malicous attacker with a valid account to transfer any plant into his/her account.
CVE-2025-10353 1 Melistechnology 1 Melis Platform 2026-04-15 N/A
File upload leading to remote code execution (RCE) in the “melis-cms-slider” module of Melis Technology's Melis Platform. This vulnerability allows an attacker to upload a malicious file via a POST request to '/melis/MelisCmsSlider/MelisCmsSliderDetails/saveDetailsForm' using the 'mcsdetail_img' parameter.
CVE-2025-10910 2026-04-15 N/A
A flaw in the binding process of Govee’s cloud platform and devices allows a remote attacker to bind an existing, online Govee device to the attacker’s account, resulting in full control of the device and removal of the device from its legitimate owner’s account. The server‑side API allows device association using a set of identifiers: "device", "sku", "type", and a client‑computed "value", that are not cryptographically bound to a secret originating from the device itself. The vulnerability has been verified for the Govee H6056 - lamp device in firmware version 1.08.13, but may affect also other Govee cloud‑connected devices. The vendor is investigating other potentially affected models. The vendor has deployed server-side security enhancements and automatic firmware updates for model H6056. Most of H6056 devices have been successfully patched through automatic updates. Remaining H6056 users with upgradeable hardware versions must manually update firmware through the Govee Home app while keeping their device WiFi-connected. Users should open the Govee Home app, tap their H6056 device card to enter the device details page, tap the settings icon in the upper right corner, navigate to Device Information section (Firmware Version), and tap the Update button to install the security patch immediately. Govee H6056 devices with hardware versions 1.00.10 or 1.00.11 cannot receive firmware update due to hardware limitations.
CVE-2025-7783 2026-04-15 5.4 Medium
Use of Insufficiently Random Values vulnerability in form-data allows HTTP Parameter Pollution (HPP). This vulnerability is associated with program files lib/form_data.Js. This issue affects form-data: < 2.5.4, 3.0.0 - 3.0.3, 4.0.0 - 4.0.3.
CVE-2025-34039 1 Yonyou 1 Ufida-nc 2026-04-15 N/A
A code injection vulnerability exists in Yonyou UFIDA NC v6.5 and prior due to the exposure of the BeanShell testing servlet (bsh.servlet.BshServlet) without proper access controls. The servlet allows unauthenticated remote attackers to execute arbitrary Java code via the bsh.script parameter. This can be exploited to run system commands and ultimately gain full control over the target server. The issue is rooted in a third-party JAR component bundled with the application, and the servlet is accessible without authentication on vulnerable installations. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-05 UTC.
CVE-2025-8264 1 Z-push 1 Z-push-dev 2026-04-15 9 Critical
Versions of the package z-push/z-push-dev before 2.7.6 are vulnerable to SQL Injection due to unparameterized queries in the IMAP backend. An attacker can inject malicious commands by manipulating the username field in basic authentication. This allows the attacker to access and potentially modify or delete sensitive data from a linked third-party database. **Note:** This vulnerability affects Z-Push installations that utilize the IMAP backend and have the IMAP_FROM_SQL_QUERY option configured. Mitigation Change configuration to use the default or LDAP in backend/imap/config.php php define('IMAP_DEFAULTFROM', ''); or php define('IMAP_DEFAULTFROM', 'ldap');
CVE-2025-8890 1 Sdmc 1 Ne6037 2026-04-15 N/A
Firmware in SDMC NE6037 routers prior to version 7.1.12.2.44 has a network diagnostics tool vulnerable to a shell command injection attacks. In order to exploit this vulnerability, an attacker has to log in to the router's administrative portal, which by default is reachable only via LAN ports.
CVE-2025-13284 1 Thinplus 1 Thinplus 2026-04-15 9.8 Critical
ThinPLUS developed by ThinPLUS has an OS Command Injection vulnerability, allowing unauthenticated remote attackers to inject arbitrary OS commands and execute them on the server.
CVE-2025-64125 1 Nuvation Energy 1 Ncloud Vpn Service 2026-04-15 N/A
A vulnerability in Nuvation Energy nCloud VPN Service allowed Network Boundary Bridging.This issue affected the nCloud VPN Service and was fixed on 2025-12-1 (December, 2025). End users do not have to take any action to mitigate the issue.
CVE-2025-24480 2026-04-15 N/A
A Remote Code Execution Vulnerability exists in the product and version listed above. The vulnerability is due to lack of input sanitation and could allow a remote attacker to run commands or code as a high privileged user.
CVE-2025-24800 2026-04-15 N/A
Hyperbridge is a hyper-scalable coprocessor for verifiable, cross-chain interoperability. A critical vulnerability was discovered in the ismp-grandpa crate, that allowed a malicious prover easily convince the verifier of the finality of arbitrary headers. This could be used to steal funds or compromise other kinds of cross-chain applications. This vulnerability is fixed in 15.0.1.
CVE-2025-34068 2026-04-15 N/A
An unauthenticated remote command execution vulnerability exists in Samsung WLAN AP WEA453e firmware prior to version 5.2.4.T1 via improper input validation in the “Tech Support” diagnostic functionality. The command1 and command2 POST or GET parameters accept arbitrary shell commands that are executed with root privileges on the underlying operating system. An attacker can exploit this by crafting a request that injects shell commands to create output files in writable directories and then access their contents via the download endpoint. This flaw allows complete compromise of the device without authentication. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-04 UTC.
CVE-2024-49775 2026-04-15 9.8 Critical
A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2501.0001), Opcenter Intelligence (All versions < V2501.0001), Opcenter Quality (All versions < V2512), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 3), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions if operated in conjunction with UMC < V2.15), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code.
CVE-2025-34055 2026-04-15 N/A
An OS command injection vulnerability exists in AVTECH DVR, NVR, and IP camera devices within the adcommand.cgi endpoint, which interfaces with the ActionD daemon. Authenticated users can invoke the DoShellCmd operation, passing arbitrary input via the strCmd parameter. This input is executed directly by the system shell without sanitation allowing attackers to execute commands as the root user.
CVE-2025-34056 2026-04-15 N/A
An OS command injection vulnerability exists in AVTECH IP camera, DVR, and NVR devices via the PwdGrp.cgi endpoint, which handles user and group management operations. Authenticated users can supply input through the pwd or grp parameters, which are directly embedded into system commands without proper sanitation. This allows for the execution of arbitrary shell commands with root privileges.