| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Improper neutralization of input provided by an unauthorized user into changes__reference_id parameter in URL allows for boolean-based Blind SQL Injection attacks. |
| An unauthenticated OS command injection vulnerability exists within Xdebug versions 2.5.5 and earlier, a PHP debugging extension developed by Derick Rethans. When remote debugging is enabled, Xdebug listens on port 9000 and accepts debugger protocol commands without authentication. An attacker can send a crafted eval command over this interface to execute arbitrary PHP code, which may invoke system-level functions such as system() or passthru(). This results in full compromise of the host under the privileges of the web server user. |
| A stack-based buffer overflow exists in the UtilConfigHome.csp endpoint of InterSystems Caché 2009.1. The vulnerability is triggered by sending a specially crafted HTTP GET request containing an oversized argument to the .csp handler. Due to insufficient bounds checking, the input overflows a stack buffer, allowing an attacker to overwrite control structures and execute arbitrary code. It is unknown if this vulnerability was patched and an affected version range remains undefined. |
| AutomationDirect C-more EA9 HMI contains a function with bounds checks that can be skipped, which could result in an attacker abusing the function to cause a denial-of-service condition or achieving remote code execution on the affected device. |
| A vulnerability has been identified in SIMATIC Virtualization as a Service (SIVaaS) (All versions). The affected application exposes a network share without any authentication. This could allow an attacker to access or alter sensitive data without proper authorization. |
| SQL injection vulnerability in AES Multimedia's Gestnet v1.07. This vulnerability allows an attacker to retrieve, create, update and delete databases via the ‘fk_remoto_central’ parameter on the ‘/webservices/articles.php’ endpoint. |
| SQL injection vulnerability in Comerzzia Backoffice: Sales Orchestrator 3.0.15. This vulnerability allows an attacker to retrieve, create, update and delete databases via the ‘uidActivity’, ‘codCompany’ and ‘uidInstance’ parameters of the ‘/comerzzia/login’ endpoint. |
| SQL injection vulnerability in DomainsPRO 1.2. This vulnerability could allow an attacker to retrieve, create, update and delete databases via the “d” parameter in the “/article.php” endpoint. |
| Multiple wireless router models from Sapido have an OS Command Injection vulnerability, allowing unauthenticated remote attackers to inject arbitrary OS commands and execute them on the server. The affected models are out of support; replacing the device is recommended. |
| A security issue exists due to improper handling of malformed CIP Forward Close packets during fuzzing. The controller enters a solid red Fault LED state and becomes unresponsive. Upon power cycle, the controller will enter recoverable fault where the MS LED and Fault LED become flashing red and reports fault code 0xF015. To recover, clear the fault. |
| The server lacks thread safety and can be crashed by anomalous data sent by an anonymous user from a remote network. The crash causes the FTP service to become unavailable, affecting all users and processes that rely on it for file transfers. If the crash occurs during file upload or download, it could lead to incomplete file transfers, potentially corrupting data. The repeated crash might also affect the stability of the underlying system, especially if it leads to resource leaks or affects other services. |
| The embedded web server on the thermostat listed version ranges contain a vulnerability that allows unauthenticated attackers, either on the local area network or from the Internet via a router with port forwarding set up, to gain direct access to the thermostat's embedded web server and reset user credentials by manipulating specific elements of the embedded web interface. |
| Wp2Fac 1.0 contains an OS command injection vulnerability in the send.php endpoint that allows remote attackers to execute arbitrary system commands. Attackers can inject shell commands through the 'numara' parameter by appending shell commands with '&' operators to execute malicious code. |
| An attacker could modify or disable settings, disrupt fuel monitoring
and supply chain operations, leading to disabling of ATG monitoring.
This would result in potential safety hazards in fuel storage and
transportation. |
| Jupyter Remote Desktop Proxy allows you to run a Linux Desktop on a JupyterHub. jupyter-remote-desktop-proxy was meant to rely on UNIX sockets readable only by the current user since version 3.0.0, but when used with TigerVNC, the VNC server started by jupyter-remote-desktop-proxy were still accessible via the network. This vulnerability does not affect users having TurboVNC as the vncserver executable. This issue is fixed in 3.0.1. |
| The equipment initially can be configured using the manufacturer's application, by Wi-Fi, by the web server or with the manufacturer’s software.
Using the manufacturer's software, the device can be configured via UDP. Analyzing this communication, it has been observed that any aspect of the initial configuration can be changed by means of the device's MAC without the need for authentication. |
| Os command injection vulnerability in e-solutions e-management. This vulnerability allows an attacker to execute arbitrary commands on the server via the ‘client’ parameter in the /data/apache/e-management/api/api3.php endpoint. |
| Remote code execution vulnerability in RSForm!pro component 3.0.0 - 3.3.14 for Joomla was discovered. The issue occurs within the submission export feature and requires administrative access to the export feature. |
| A vulnerability has been identified in Opcenter Quality (All versions < V2406), Opcenter RDnL (All versions < V2410), SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SINEC NMS (All versions), SINEMA Remote Connect Client (All versions < V3.2 SP3), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 5), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 3). Affected products contain a heap-based buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to execute arbitrary code. |
| This vulnerability allows the successful attacker to gain unauthorized access to a
configuration web page delivered by the integrated web Server of EIBPORT.
This issue affects EIBPORT V3 KNX: through 3.9.8; EIBPORT V3 KNX GSM: through 3.9.8. |