| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An exposed IOCTL with an insufficient access control vulnerability has been identified in the utility, MxGeneralIo, for Moxa’s industrial x86 computers. The affected utility, MxGeneralIo, exposes IOCTL methods that permit direct read and write access to MSR and system memory. A local attacker with high privileges could abuse these interfaces to perform unauthorized operations. Successful exploitation may result in privilege escalation on Windows 7 systems or cause a system crash (BSoD) on Windows 10 and 11 systems, leading to a denial-of-service condition. The vulnerability could slightly affect the confidentiality and integrity of the device, but availability might be heavily impacted. No impact to the subsequent system has been identified. |
| A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="switch_contact" |
| A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="Switch Description", name "switch_description" |
| A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="webLocationMessage_text" name="webLocationMessage_text" |
| An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. The web application may not sufficiently verify whether a request was provided by a valid user (CROSS-SITE REQUEST FORGERY). |
| A Credentials Management issue was discovered in Moxa NPort W2150A versions prior to 1.11, and NPort W2250A versions prior to 1.11. The default password is empty on the device. An unauthorized user can access the device without a password. An unauthorized user has the ability to completely compromise the confidentiality and integrity of the wireless traffic. |
| Moxa MXView 2.8 allows remote attackers to cause a Denial of Service by sending overly long junk payload for the MXView client login credentials. |
| An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. A configuration file contains parameters that represent passwords in plaintext. |
| An issue was discovered in Moxa MiiNePort E1 versions prior to 1.8, E2 versions prior to 1.4, and E3 versions prior to 1.1. Configuration data are stored in a file that is not encrypted. |
| Moxa MXView 2.8 allows remote attackers to read web server's private key file, no access control. |
| An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. Users are restricted to using short passwords. |
| An exploitable Cleartext Transmission of Password vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. The Change Password functionality of the Web Application transmits the password in cleartext. An attacker capable of intercepting this traffic is able to obtain valid credentials. |
| An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. A password is transmitted in a format that is not sufficiently secure. |
| XML External Entity via ".AOP" files used by Moxa MX-AOPC Server 1.5 result in remote file disclosure. |
| An exploitable nonce reuse vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless AP running firmware 1.1. The device uses one nonce for all session authentication requests and only changes the nonce if the web application has been idle for 300 seconds. |
| An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. A specially crafted URL request sent to the SoftCMS ASP Webserver can cause a double free condition on the server allowing an attacker to modify memory locations and possibly cause a denial of service or the execution of arbitrary code. |
| An exploitable information disclosure vulnerability exists in the serviceAgent functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. A specially crafted TCP query will allow an attacker to retrieve potentially sensitive information. |
| An issue was discovered in Moxa MiiNePort E1 versions prior to 1.8, E2 versions prior to 1.4, and E3 versions prior to 1.1. An attacker may be able to brute force an active session cookie to be able to download configuration files. |
| An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. The SoftCMS Application does not properly sanitize input that may allow a remote attacker access to SoftCMS with administrator's privilege through specially crafted input (SQL INJECTION). |
| An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. Moxa SoftCMS Webserver does not properly validate input. An attacker could provide unexpected values and cause the program to crash or excessive consumption of resources could result in a denial-of-service condition. |