An attacker with administrative access on the device who obtains the affected diagnostic data could recover sensitive authentication information. This could potentially compromise the confidentiality and integrity of traffic protected by MACsec on the affected link.
The vulnerability is only exposed during and after an SSU reload where an active 802.1X session used for MACsec is present.
No advisories yet.
Solution
No solution given by the vendor.
Workaround
No workaround given by the vendor.
Tue, 17 Nov 2026 02:30:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
Thu, 12 Nov 2026 17:30:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Arista
Arista eos |
|
| Vendors & Products |
Arista
Arista eos |
Tue, 10 Nov 2026 20:15:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | On affected platforms running Arista EOS with IEEE 802.1X authentication and MACsec using dynamically derived keys, sensitive authentication information may be recorded in diagnostic data during a Smart Switch Upgrade (SSU). An attacker with administrative access on the device who obtains the affected diagnostic data could recover sensitive authentication information. This could potentially compromise the confidentiality and integrity of traffic protected by MACsec on the affected link. The vulnerability is only exposed during and after an SSU reload where an active 802.1X session used for MACsec is present. | |
| Title | Security Advisory 0216 | |
| Weaknesses | CWE-532 | |
| References |
| |
| Metrics |
cvssV3_1
|
Projects
Sign in to view the affected projects.
Status: PUBLISHED
Assigner: Arista
Published:
Updated: 2026-11-16T19:28:13.882Z
Reserved: 2026-11-03T05:14:06.127Z
Link: CVE-2026-120976
Updated: 2026-11-16T19:28:08.647Z
Status : Awaiting Analysis
Published: 2026-11-10T20:18:52.660
Modified: 2026-11-16T20:18:48.877
Link: CVE-2026-120976
No data.
OpenCVE Enrichment
Updated: 2026-11-13T11:45:20Z