Export limit exceeded: 17252 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (17252 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-42934 1 Sap 1 S/4hana 2026-04-15 4.3 Medium
SAP S/4HANA Supplier invoice is vulnerable to CRLF Injection. An attacker with user-level privileges can bypass the allowlist and insert untrusted sites into the 'Trusted Sites' configuration by injecting line feed (LF) characters into application inputs. This vulnerability has a low impact on the application's integrity and no impact on confidentiality or availability.
CVE-2024-1174 1 Hp 1 Thinpro 2026-04-15 8.2 High
Previous versions of HP ThinPro (prior to HP ThinPro 8.0 SP 8) could potentially contain security vulnerabilities. HP has released HP ThinPro 8.0 SP 8, which includes updates to mitigate potential vulnerabilities.
CVE-2025-10385 1 Mercury 1 Km08-708h Giga Wifi Wave2 2026-04-15 8.8 High
A vulnerability has been found in Mercury KM08-708H GiGA WiFi Wave2 1.1. Affected by this issue is the function sub_450B2C of the file /goform/mcr_setSysAdm. The manipulation of the argument ChgUserId leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-11085 1 Rockwellautomation 1 Factorytalk 2026-04-15 N/A
A security issue exists within DataMosaix™ Private Cloud allowing for Persistent XSS. This vulnerability can result in the execution of malicious JavaScript, allowing for account takeover, credential theft, or redirection to a malicious website.
CVE-2025-5555 1 Dieboldnixdorf 1 Wincor 2026-04-15 7.8 High
A vulnerability has been found in Nixdorf Wincor PORT IO Driver up to 1.0.0.1. This affects the function sub_11100 in the library wnport.sys of the component IOCTL Handler. Such manipulation leads to stack-based buffer overflow. Local access is required to approach this attack. The exploit has been disclosed to the public and may be used. Upgrading to version 3.0.0.1 is able to mitigate this issue. Upgrading the affected component is recommended. The vendor was contacted beforehand and was able to provide a patch very early.
CVE-2025-53094 2026-04-15 N/A
ESPAsyncWebServer is an asynchronous HTTP and WebSocket server library for ESP32, ESP8266, RP2040 and RP2350. In versions up to and including 3.7.8, a CRLF (Carriage Return Line Feed) injection vulnerability exists in the construction and output of HTTP headers within `AsyncWebHeader.cpp`. Unsanitized input allows attackers to inject CR (`\r`) or LF (`\n`) characters into header names or values, leading to arbitrary header or response manipulation. Manipulation of HTTP headers and responses can enable a wide range of attacks, making the severity of this vulnerability high. A fix is available at pull request 211 and is expected to be part of version 3.7.9.
CVE-2024-25972 1 Atsumi 1 Oet-213h-bts1 2026-04-15 8.3 High
Initialization of a resource with an insecure default vulnerability in OET-213H-BTS1 sold in Japan by Atsumi Electric Co., Ltd. allows a network-adjacent unauthenticated attacker to configure and control the affected product.
CVE-2025-2401 2026-04-15 N/A
Buffer overflow vulnerability in Immunity Debugger affecting version 1.85, its exploitation could allow a local attacker to execute arbitrary code, due to the lack of proper boundary checking.
CVE-2025-7213 1 Fnkvision 1 Fnk-gu2 2026-04-15 6.4 Medium
A vulnerability classified as critical has been found in FNKvision FNK-GU2 up to 40.1.7. Affected is an unknown function of the component UART Interface. The manipulation leads to on-chip debug and test interface with improper access control. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used.
CVE-2024-30253 2026-04-15 7.5 High
@solana/web3.js is the Solana JavaScript SDK. Using particular inputs with `@solana/web3.js` will result in memory exhaustion (OOM). If you have a server, client, mobile, or desktop product that accepts untrusted input for use with `@solana/web3.js`, your application/service may crash, resulting in a loss of availability. This vulnerability is fixed in 1.0.1, 1.10.2, 1.11.1, 1.12.1, 1.1.2, 1.13.1, 1.14.1, 1.15.1, 1.16.2, 1.17.1, 1.18.1, 1.19.1, 1.20.3, 1.21.1, 1.22.1, 1.23.1, 1.24.3, 1.25.1, 1.26.1, 1.27.1, 1.28.1, 1.2.8, 1.29.4, 1.30.3, 1.31.1, 1.3.1, 1.32.3, 1.33.1, 1.34.1, 1.35.2, 1.36.1, 1.37.3, 1.38.1, 1.39.2, 1.40.2, 1.41.11, 1.4.1, 1.42.1, 1.43.7, 1.44.4, 1.45.1, 1.46.1, 1.47.5, 1.48.1, 1.49.1, 1.50.2, 1.51.1, 1.5.1, 1.52.1, 1.53.1, 1.54.2, 1.55.1, 1.56.3, 1.57.1, 1.58.1, 1.59.2, 1.60.1, 1.61.2, 1.6.1, 1.62.2, 1.63.2, 1.64.1, 1.65.1, 1.66.6, 1.67.3, 1.68.2, 1.69.1, 1.70.4, 1.71.1, 1.72.1, 1.7.2, 1.73.5, 1.74.1, 1.75.1, 1.76.1, 1.77.4, 1.78.8, 1.79.1, 1.80.1, 1.81.1, 1.8.1, 1.82.1, 1.83.1, 1.84.1, 1.85.1, 1.86.1, 1.87.7, 1.88.1, 1.89.2, 1.90.2, 1.9.2, and 1.91.3.
CVE-2024-41692 1 Syrotech 1 Sy-gpon-1110-wdont Firmware 2026-04-15 N/A
This vulnerability exists in SyroTech SY-GPON-1110-WDONT Router due to presence of root terminal access on a serial interface without proper access control. An attacker with physical access could exploit this by accessing the root shell on the vulnerable system. Successful exploitation of this vulnerability could allow the attacker to execute arbitrary commands with root privileges on the targeted system.
CVE-2025-2521 2026-04-15 8.6 High
The Honeywell Experion PKS and OneWireless WDM contains a Memory Buffer vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to an Overread Buffers, which could result in improper index validation against buffer borders leading to remote code execution. Honeywell recommends updating to the most recent version of Honeywell Experion PKS: 520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1. The affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3.
CVE-2025-26503 1 Windriver 1 Vxworks 2026-04-15 6.7 Medium
A crafted system call argument can cause memory corruption.
CVE-2024-34063 2026-04-15 2.5 Low
vodozemac is an implementation of Olm and Megolm in pure Rust. Versions 0.5.0 and 0.5.1 of vodozemac have degraded secret zeroization capabilities, due to changes in third-party cryptographic dependencies (the Dalek crates), which moved secret zeroization capabilities behind a feature flag and defaulted this feature to off. The degraded zeroization capabilities could result in the production of more memory copies of encryption secrets and secrets could linger in memory longer than necessary. This marginally increases the risk of sensitive data exposure. This issue has been addressed in version 0.6.0 and users are advised to upgrade. There are no known workarounds for this vulnerability.
CVE-2025-31930 2026-04-15 8.8 High
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.
CVE-2025-55903 2026-04-15 8.3 High
A HTML injection vulnerability exists in Perfex CRM v3.3.1. The application fails to sanitize user input in the "Bill To" address field within the estimate module. As a result, arbitrary HTML can be injected and rendered unescaped in client-facing documents.
CVE-2023-46586 1 Weborf Project 1 Weborf 2026-04-15 9.1 Critical
cgi.c in weborf .0.17, 0.18, 0.19, and 0.20 (before 1.0) lacks '\0' termination of the path for CGI scripts because strncpy is misused.
CVE-2024-4162 2026-04-15 4.4 Medium
A buffer error in Panasonic KW Watcher versions 1.00 through 2.83 may allow attackers malicious read access to memory.
CVE-2025-41438 2026-04-15 9.8 Critical
The CS5000 Fire Panel is vulnerable due to a default account that exists on the panel. Even though it is possible to change this by SSHing into the device, it has remained unchanged on every installed system observed. This account is not root but holds high-level permissions that could severely impact the device's operation if exploited.
CVE-2025-6751 1 Linksys 1 E8450 2026-04-15 8.8 High
A vulnerability, which was classified as critical, was found in Linksys E8450 up to 1.2.00.360516. This affects the function set_device_language of the file portal.cgi of the component HTTP POST Request Handler. The manipulation of the argument dut_language leads to buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.